Effect of zinc on prestressing steel

Effect of zinc on prestressing steel
Author :
Publisher : fib Fédération internationale du béton
Total Pages : 28
Release :
ISBN-10 : 9782883941045
ISBN-13 : 2883941041
Rating : 4/5 (45 Downloads)

Book Synopsis Effect of zinc on prestressing steel by : fib Fédération internationale du béton

Download or read book Effect of zinc on prestressing steel written by fib Fédération internationale du béton and published by fib Fédération internationale du béton. This book was released on 2012-06-01 with total page 28 pages. Available in PDF, EPUB and Kindle. Book excerpt: Concerns have been raised regarding the durability of galvanized prestressing steels in contact with cementitious grout, and regarding the use of galvanized ducts for grouted tendons or galvanized inserts or components in contact with prestressing steel inside concrete. These concerns are mainly based on the assumption that the hydrogen formed on the zinc surface when exposed to the fresh cementitious grout for a short period of time represents a risk of hydrogen induced stress corrosion for the prestressing steel. Basic research has demonstrated that hydrogen induced stress corrosion may indeed occur with prestressing steels which are sensitive to hydrogen induced stress corrosion. The use of galvanizing for high strength steels exposed to atmosphere is less controversial. However, under certain conditions hydrogen may develop also and potentially damage the high strength steel. This report provides a summary and evaluation of the relevant parameters on the corrosion behaviour of high strength wires, strands and bars when in contact with zinc with and without the presence of fresh cementitious grout or concrete. Both, tendons made of prestressing steels used in structural concrete and cables under atmospheric conditions are considered. The main groups of applications discussed in the report are: A Zinc-coated high strength steel for applications in atmospheric corrosion conditions B Zinc-coated prestressing steel embedded in fresh cementitious grout or concrete C Bare prestressing steel (no zinc coating) embedded in fresh cementitious grout or concrete in direct contact with, or indirect contact in the immediate vicinity of galvanized components embedded in the grout or concrete (e.g. galvanized ducts, galvanized reinforcing steel, galvanized fastenings / dowels, etc).


Effect of zinc on prestressing steel Related Books

Effect of zinc on prestressing steel
Language: en
Pages: 28
Authors: fib Fédération internationale du béton
Categories: Technology & Engineering
Type: BOOK - Published: 2012-06-01 - Publisher: fib Fédération internationale du béton

DOWNLOAD EBOOK

Concerns have been raised regarding the durability of galvanized prestressing steels in contact with cementitious grout, and regarding the use of galvanized duc
Acceptance of stay cable systems using prestressing steels
Language: en
Pages: 126
Authors: FIB – International Federation for Structural Concrete
Categories: Technology & Engineering
Type: BOOK - Published: 2019-03-01 - Publisher: FIB - International Federation for Structural Concrete

DOWNLOAD EBOOK

Cable-stayed structures have become increasingly popular over the last 30 years and have been used in all parts of the world. Modern cable-stayed bridges have a
Factory Applied Corrosion Protection of Prestressing Steel
Language: en
Pages: 24
Authors: fib Fédération internationale du béton
Categories: Technology & Engineering
Type: BOOK - Published: 2001-01-01 - Publisher: fib Fédération internationale du béton

DOWNLOAD EBOOK

Without doubt, active corrosion protection of prestressing steels by cement grout can be one of the most economic and durable solutions, if properly executed. N
Polymer-duct systems for internal bonded post-tensioning
Language: en
Pages: 183
Authors: fib Fédération internationale du béton
Categories: Technology & Engineering
Type: BOOK - Published: 2014-12-01 - Publisher: fib Fédération internationale du béton

DOWNLOAD EBOOK

The purpose of this recommendation - fib Bulletin 75: Polymer-duct systems for internal bonded post-tensioning - is to update and amend fib Bulletin 7:Corrugate
Zinc in Its Corrosion Resistance ...
Language: en
Pages: 94
Authors: Research Service, Incorporated
Categories: Corrosion and anti-corrosives
Type: BOOK - Published: 1928 - Publisher:

DOWNLOAD EBOOK