The Use of an On-board MV Imager for Plan Verification of Intensity Modulated Radiation Therapy and Volumetrically Modulated Arc Therapy

The Use of an On-board MV Imager for Plan Verification of Intensity Modulated Radiation Therapy and Volumetrically Modulated Arc Therapy
Author :
Publisher :
Total Pages : 71
Release :
ISBN-10 : OCLC:858628810
ISBN-13 :
Rating : 4/5 (10 Downloads)

Book Synopsis The Use of an On-board MV Imager for Plan Verification of Intensity Modulated Radiation Therapy and Volumetrically Modulated Arc Therapy by : Justin A. Walker

Download or read book The Use of an On-board MV Imager for Plan Verification of Intensity Modulated Radiation Therapy and Volumetrically Modulated Arc Therapy written by Justin A. Walker and published by . This book was released on 2013 with total page 71 pages. Available in PDF, EPUB and Kindle. Book excerpt: The introduction of complex treatment modalities such as IMRT and VMAT has led to the development of many devices for plan verification. One such innovation in this field is the repurposing of the portal imager to not only be used for tumor localization but for recording dose distributions as well. Several advantages make portal imagers attractive options for this purpose. Very high spatial resolution allows for better verification of small field plans than may be possible with commercially available devices. Because the portal imager is attached to the gantry set up is simpler than any other method available, requiring no additional accessories, and often can be accomplished from outside the treatment room. Dose images capture by the portal imager are in digital format make permanent records that can be analyzed immediately. Portal imaging suffers from a few limitations however that must be overcome. Images captured contain dose information and a calibration must be maintained for image to dose conversion. Dose images can only be taken perpendicular to the treatment beam allowing only for planar dose comparison. Planar dose files are themself difficult to obtain for VMAT treatments and an in-house script had to be developed to create such a file before analysis could be performed. Using the methods described in this study, excellent agreement between planar dose files generated and dose images taken were found. The average agreement for IMRT field analyzed being greater than 97% for non-normalized images at 3mm and 3%. Comparable agreement for VAMT plans was found as well with the average agreement being greater than 98%.


The Use of an On-board MV Imager for Plan Verification of Intensity Modulated Radiation Therapy and Volumetrically Modulated Arc Therapy Related Books

The Use of an On-board MV Imager for Plan Verification of Intensity Modulated Radiation Therapy and Volumetrically Modulated Arc Therapy
Language: en
Pages: 71
Authors: Justin A. Walker
Categories:
Type: BOOK - Published: 2013 - Publisher:

DOWNLOAD EBOOK

The introduction of complex treatment modalities such as IMRT and VMAT has led to the development of many devices for plan verification. One such innovation in
Total Marrow Irradiation
Language: en
Pages: 0
Authors: Jeffrey Y. C. Wong
Categories: Medical
Type: BOOK - Published: 2021-03-01 - Publisher: Springer

DOWNLOAD EBOOK

This book, written by a team of international experts, concisely reviews the rationale and clinical application of image-guided total marrow irradiation, a rapi
Oncologic Imaging
Language: en
Pages: 0
Authors: David G. Bragg
Categories: Cancer
Type: BOOK - Published: 2002 - Publisher: Saunders

DOWNLOAD EBOOK

Completely updated to reflect the latest developments in science and technology, the second edition of this reference presents the diagnostic imaging tools esse
A Comparative Analysis for Verification of IMRT and VMAT Treatment Plans Using a 2-D and 3-D Diode Array
Language: en
Pages: 64
Authors: Michael Joseph Dance
Categories:
Type: BOOK - Published: 2014 - Publisher:

DOWNLOAD EBOOK

With the added complexity of current radiation treatment dose delivery modalities such as IMRT (Intensity Modulated Radiation Therapy) and VMAT (Volumetric Modu
Stereotactic Body Radiation Therapy
Language: en
Pages: 433
Authors: Simon S. Lo
Categories: Medical
Type: BOOK - Published: 2012-08-28 - Publisher: Springer Science & Business Media

DOWNLOAD EBOOK

Stereotactic body radiation therapy (SBRT) has emerged as an important innovative treatment for various primary and metastatic cancers. This book provides a com